Richmar TheraTouch CX4 Advanced Clinical 4-Channel Electrotherapy & Ultrasound Combo System

SKU: DQ8200
Digital Touch Screen with Clinical Protocol and Programmable Favorites | DQ8200
TheraTouch CX4 E-Stim & Ultrasound Combo Unit with Rolling Cart | DQ8001
Optional Rolling Cart with Multi-Drawer Storage System
Multi-Functional Touchscreen Interface
Clinical Protocols Provide The Appropriate Parameters For A Variety Of Conditions
Clinically Developed & Approved Educational Library

Richmar TheraTouch CX4 Advanced Clinical 4-Channel Electrotherapy & Ultrasound Combo System

SKU: DQ8200
Regular price $3,999.00 Sale price $2,995.95 Save 25%
/
Shipping calculated at checkout.
  • Fast Shipping
  • 30-Day Return Policy
  • FDA Approved
  • Secure Payments
  • In stock
  • Inventory on the way
Richmar

The Richmar TheraTouch CX4, formerly the InTENSity™ CX4, is an advanced combination four-channel electrotherapy and ultrasound therapy system, offering the practitioner a wide range of treatment options in one user-friendly, ergonomic design.
 
Equipped with a menu-driven color screen with touch interface that intuitively groups and displays clinical protocols, guiding clinicians step-by-step to ensure the ideal therapeutic treatment.
  • Electrotherapy waveform rationale
  • Appropriate parameter settings
  • Electrode placement guide
  • Ultrasound applicator recommendations

A few simple key presses are all that is needed to quick-start a treatment. Parameters can be easily selected and adjusted. Clinicians can choose to use preset clinical protocols or customize their own. The “Favorites” feature allows user-defined protocols to be stored for future use.

The four electrotherapy channels can be used in combination with ultrasound, or totally independent, with different protocols running simultaneously. The ergonomically designed 5 cm² sound head provides for an excellent ERA.

  • Interferential (Premodulated 2-Pole & Traditional 4-Pole)
  • TENS (Biphasic)
  • Neuromuscular Stimulation (EMS/NMS)
  • Russian Stim
  • High Volt Pulsed Current (HVPC)
  • Microcurrent
  • Therapeutic Ultrasound
  • RAAS (Rapid Agonist & Antagonist Sequencing)


In addition, the TheraTouch CX4 offers a comprehensive library with treatment education and suggested electrode placement for better treatment outcome and improved clinic efficiency.


Features
:

  • Combination electrotherapy and ultrasound therapy system
  • 4 channels of independent stimulation can be used in combination (linked) or totally independent
  • Multi-patient function provides the ability to treat up to three patients at once for maximum practice usage
  • Independent intensity and parameter controls for each channel
  • Sleek, user-friendly, ergonomic design for table top or therapy cart use
  • Large, easy-to-read, color LCD display with touch screen interface
  • Multiple waveform electrotherapy with six clinical waveform modalities
  • Clinical protocols providing the appropriate parameters for a variety of acute and chronic conditions
  • Manual operation allows for user-defined protocols
  • “Favorites” feature allows storage of up to 99 custom programs for future use
  • Comprehensive library provides treatment education and suggested electrode placement
  • Patient Remote Kill Switch connection allows patient to stop treatment at the push of a button
  • 1 and 3 MHz ultrasound frequencies
  • Pulsed and Continuous Modes
  • Ergonomically designed 5 cm² sound head for excellent ERA during treatments (1 cm² sound head optional)
  • Low BNR ratio of 5:1
  • Ultrasound Amplitude can be toggled between w and w/cm²
  • Sound head coupling feature
  • Optional therapy cart (DQCART-2), sold separately, integrates with the unit and keeps supplies organized and ready for treatments
  • Three-year Manufacturer Warranty


Technical Specifications
:

  • Number of Channels: Four, Isolated
  • Treatment Time: 1-60 min, adjustable
  • Power Supply: 100-240 VAC, 50-60 Hz
  • Dimensions (LxWxH): 11.25” x 7.75” x 9.5”
  • Weight: 6 lbs.
  • UPC: 092237615218

View Operation Manual

Thank you for reaching out to LSI International! We're here to assist you with any questions, concerns, or feedback you may have. You can contact us directly using the information provided below, or simply fill out our contact form for a prompt response.


Direct Contact Information:

  • Phone: 800-832-0053
  • Email: sales@lsiinternational.com
  • Address: LSI International, 1131 N Warson Rd Bldg D St. Louis, MO 63132, United States

Your feedback and inquiries are important to us. We strive to respond to all messages as swiftly as possible. Thank you for choosing LSI International, and we look forward to assisting you!

We have a 30-day return policy, which means you have 30 days after receiving your item to request a return. To be eligible for a return, your item must be in the same condition that you received it, unworn or unused, with tags, and in its original packaging. You’ll also need the receipt or proof of purchase. To start a return, you can contact us at lsiinternationalcorp@gmail.com. If your return is accepted, we’ll send you a return shipping label, as well as instructions on how and where to send your package. Items sent back to us without first requesting a return will not be accepted. You can always contact us for any return question at lsiinternationalcorp@gmail.com. Damages and issues Please inspect your order upon reception and contact us immediately if the item is defective, damaged or if you receive the wrong item, so that we can evaluate the issue and make it right. Exceptions / non-returnable items Your satisfaction with LSI International, and the products you purchase, is of the highest importance to us. We will gladly accept the return, or exchange, of most products up to 30 days from the date of purchase. The return of any allowed products that have been opened, used, or have broken seals are subject to a 20% restocking fee. Original shipping and handling charges incurred are always non-refundable and will be deducted from any refund for the cost of returned items, including in the event of a Free Shipping promotional incentive being applied to an order. Once a return is made, this promotional incentive is negated and the cost incurred must be accounted for. The restocking fee will only be waived in the case of all returned items being unopened, unused, and in their original packaging. Missing Instruction Manuals, Quick Reference Guides, and any other original literature from a returned product will result in an automatic $5.00 fee deducted from any refunds issued for the costs of those items. If you are unsatisfied with a product, or find any defects due to manufacturing and/or workmanship, please contact us. Fulfillment mistakes that we make, resulting in the shipment of incorrect products to you, will also be accepted for return up to 30 days from the date of purchase. To make a return, or exchange, please contact Customer Service to get a Return Authorization number. We will be happy to provide the number and explain the procedure to you. Our process is simple - Clearly write the return authorization number on the outside of the product packaging so we can easily identify the order, ship to our warehouse, and we will credit the account used to make the purchase within 7 business days from the date we receive the returned items, or contact you to complete an exchange. Returns or exchanges cannot be accepted without a return authorization number. If your item was damaged during shipment, please contact us for assistance. Our customer service line is available M-F from 9am-5pm CST at (800)-832-0053, or feel free to lsiinternationalcorp@gmail.com. If you experience any issues, or technical difficulties, with a product you ordered, please contact Customer Service. This would be tied to a manufacturer warranty process and we will be more than happy to set up a technical support call for you. Ultrasound Returns: Portable Ultrasound may only be returned if the product has NOT been used. Used Ultrasound devices may not be returned due to sanitary health reasons set by the FDA. If you are attempting to return the device due to defect or malfunction with performance, this would go through the warranty and we ask you to please contact us for a warranty claim. Pillows and Cushions: Any pillows or cushions may only be returned if they are unused and in the same condition customer received the item with original packaging. We only sell our pillows and cushions brand new for sanitary reasons. Exchanges The fastest way to ensure you get what you want is to return the item you have, and once the return is accepted, make a separate purchase for the new item. Refunds We will notify you once we’ve received and inspected your return, and let you know if the refund was approved or not. If approved, you’ll be automatically refunded on your original payment method. Please remember it can take some time for your bank or credit card company to process and post the refund too.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

The Hottest Laser Therapy Device On The Market!
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator
from $3,595.95
Richmar TheraTouch UX2 Clinical Ultrasound Therapy Device
$2,095.00
Richmar THERADOT Deep Oscillation Therapy Device
$5,295.00
Recently viewed