Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator

SKU: DQLLLT
The Hottest Laser Therapy Device On The Market!
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator
9 Diode Cluster Applicator
Single Diode Cluster Applicator
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator

Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator

SKU: DQLLLT
Regular price $3,195.95
/
Shipping calculated at checkout.
  • Fast Shipping
  • 30-Day Return Policy
  • FDA Approved
  • Secure Payments
  • In stock
  • Inventory on the way




The Richmar TheraTouch® LX2 is a Class IIIb "cold laser / low-level laser" therapy device, intended for use in the clinical setting, for the treatment of a wide range of conditions, including regenerative stimulation in chronic pathologies, reduction of acute inflammation of edema, acute and chronic pain, and soft tissue syndromes.

Capable of delivering up to 35 joules/cm² per treatment that comes standard with a 850nm 9-diode cluster applicator. A single diode applicator is also available as an accessory. Like other TheraTouch products, the LX2 uses a modern touchscreen user interface with evidence-based clinical protocols to easily set up treatment for common acute and chronic conditions, and is backed by Richmar's industry-leading three-year warranty.

Intended Use:
Laser therapy is based mostly on photo-chemical and photo-biological effects on cells and tissues. Observations have shown that if the laser light is supplied in the right quantities, a stimulation of certain cellular functions will be obtained, especially in the presence of cells with functional deficiencies. The biological action in using Laser therapy produces a series of effects on the cells in function of a "stimulating" action on mitochondrial functions with a higher production of ATP.

Expect the following effects on tissues treated with the TheraTouch LX2 laser therapy device:
-Increased local blood circulation
-Acceleration of tissue healing
-Stimulation of the fibroblast cells
-Increase in collagen deposition

The TheraTouch LX2 carries out an important therapeutic action for the acceleration of the healing process, and is thus very commonly used by chiropractors, athletic trainers, and many other physiotherapists worldwide.

Indications For Cold Laser Therapy:
  • FDA-Approved For:
    • Minor muscle and joint pain
    • Arthritis and muscle spasms
    • Joint stiffness
    • Promoting relaxation of muscle tissue
    • Temporarily increasing local blood circulation
  • Other Common Applications Include:
    • General acute & chronic pain
    • Reduction of inflammation
    • Tendinopathies
    • Back Pain
    • Fibromyalgia
    • Wound healing
    • Carpal Tunnel
    • Sports injuries

Product Features & Key Points:
  • The ONLY laser therapy device on the market that comes standard with an applicator
  • Delivers up to 35 J/cm² of LLLT in a single treatment
  • Built-in dosage calculator automatically calculates & displays output in:
    - Joules
    - J/cm²
    - J/diode
  • Easy-to-use menu-driven touchscreen interface
  • Programmable treatment time up to 4 minutes
  • Continuous or Pulsed output modes
  • 2 output channels allows the simultaneous treatment of multiple body parts or 2 separate patients
  • 10 pre-defined evidence-based clinical protocols for common indications developed by leading therapy researchers
  • Save up to 100 user-defined protocols for specific patients
  • Available with optional Therapy Cart and/or Single Diode Applicator (Must Be Purchased Separately)

Product Specifications:
  • TheraTouch LX2 Device
    • Power Supply: 100-240V AC, 50/60Hz
    • Maximum Absorbed Power: 60W
    • Programmable Treatment Time: Up to 4 minutes
    • Mode Of Operation: Continuous or Pulsed
    • Emission Frequency: 1Hz - 10,000Hz
    • Pulsed Mode: 90%
    • Output Channels: 2
    • LCD Back-Lit Display: Graphic 480 X 800 pixels (TOUCH SCREEN)
    • Protocols In Memory: 10
    • Number Of Protocols That Can Be Saved In The User Memory: 100
    • Laser Classification: Class IIIb
    • Remote Interlock Connector: 1
    • Key Control: Passwords
    • Command Of Execution Of The Treatment: Button
    • Class of Isolation / Parts Applied According To Rule EN 60601-1: Class I, B-type
    • Dimensions (W x H x D): 7.75" x 9.5" x 11.2"
    • Product Weight: 5 lbs
    • Sound: Speaker
  • Single Diode Applicator (Part #: DQLLLT-SA)
    • Diode Specifications: 650nm ± 30nm
    • Maximum Power: 200mW ± 20%
    • Beam Divergence: 19° x 34°
    • Nominal Optical Hazard Distance (NOHD): 40cm
    • Cord Length: 60"
  • Multiple Diode Applicator (Part #: DQLLLT-CA)
    • Diode Specifications: 9 Diode Cluster Laser 1040 mW
      • Four 650 ± 30 nm (10 mW) [LED]
      • Five 850 ± 30 nm (200mW) [Laser]
    • Maximum Power: 1040mW ± 20%
    • Beam Divergence: 12° x 30°
    • Nominal Optical Hazard Distance (NOHD): 60cm
    • Cord Length: 60"

Application Information:
  • BEFORE TREATMENT
    • Check the patient for contraindications.
    • Before applying laser therapy, it is necessary to prepare the patients skin to allow the laser light to reach the target tissue better and to reduce skin irritation, by doing the following:
  1. Clean the area where the head of the laser will be positioned with soap and water or alcohol.
  2. Make sure to dry the area well before starting laser application.
Both operator and patient MUST wear the PROTECTIVE GLASSES.
  • DURING TREATMENT
    • Frequently ask to ensure patients are not experiencing undesired effects from treatment. If necessary the treatment will have to be adapted. The amplitude can be reduced or the continuous mode can be changed to pulsed mode or vice versa.
    • Do not look directly into the laser or remove protective glasses prior to treatment ending.
  • AFTER TREATMENT
    • Ensure the laser output has stopped before removing the protective glasses from the patient and treating clinician.
    • Observe the treatment area to ensure no undesired effects have occurred.
    • Tell the patient to inform the clinician should they have any adverse reactions.

Treatment Tips:
  • CONTACT
    • For most effective results, the applicator should be in contact with the patient's skin and may require multiple applications around the treatment area.
  • APPLICATOR SELECTION
    • For very small treatment areas, treat with the single diode applicator. For areas that are sensitive, use the single applicator first, then use the cluster applicator.
  • PRE & POST TREATMENT
    • COLD: If treating with cold therapy as part of the treatment regimen, apply cold therapy prior to laser treatment as it reduces the energy that is removed from the area and slows the flow of red blood cells.
    • HOT: If treating with hot therapy as part of the treatment regimen, apply heat after laser treatment as it increases the energy and can be removed from the area by speeding up the flow of red blood cells.

Frequently Asked Questions:
  • "Aren't Class IV lasers better than Class IIIb because they have more power?"
    • No. The majority of clinical research surrounding low-level laser therapy has been done using Class IIIb lasers. That research has shown positive outcomes for quicker tissue healing, inflammation reduction, and pain management.

  • "Should I be concerned that the laser will burn my patients?"
    • Class IV lasers have a higher risk for patient burns because they were originally developed for surgery & thermal therapy applications. Class IIIb lasers are non-thermal so the risk is minimal.

  • "Clinical laser therapy devices are very costly... Why should I buy yours?"
    • Class IV & other Class 3b laser units may indeed be costly and also do not typically come with all necessary accessories, like an applicator. The TheraTouch LX2 is the only unit on the market equipped standard with an applicator and all necessary parts to begin treatment right away, and also supported by Richmar's industry-leading 3-year manufacturer warranty, so rest assured you will always be covered and well taken care of should any technical issues ever arise.

  • "I don't know much about laser therapy and how best to apply the TheraTouch LX2 device..."
    • No worries! The heart of the LX2 is a menu-driven touchscreen interface to guide users through treatment set-up each step of the way. Research-based clinical protocols also aid in quick set-up: Just select the patient's condition or treatment goal, and you are ready to go!
    • Any questions, or assistance needed, along the way, just ask.

  • "I am not familiar with Richmar. Why should I trust this manufacturer and product?"
    • Richmar has been a leading US-based manufacturer and distributor of physiotherapy modalities and supplies for over 65 years. After inventing the very first ultrasound/electrotherapy combination device in 1958, Richmar continues to be at the forefront of innovation and trust in the industry today.

  • "I am concerned about initial set up and training for the device. Is there support available?"
    • Absolutely! The TheraTouch LX2 comes ready-to-use right outside the box. Always refer to the Operation Manual first, and if any additional training is needed, just contact your dealer to coordinate and schedule a more formal training session. The goal is to ensure that when all is said and done, you know exactly how to use the product, and feel comfortable doing so. Your dealer will always be available should any questions ever arise.

Package Contents:
  • 1x Richmar TheraTouch LX2 Device
  • 2x Laser Protective Goggles With Cleaning Cloth & Carrying Case
  • 1x AC Power Cord
  • 1x 9 Diode Cluster Applicator
  • 1x User Manual
Therapy Cart & Single Diode Applicator available as optional accessories.

Thank you for reaching out to LSI International! We're here to assist you with any questions, concerns, or feedback you may have. You can contact us directly using the information provided below, or simply fill out our contact form for a prompt response.


Direct Contact Information:

  • Phone: 800-832-0053
  • Email: sales@lsiinternational.com
  • Address: LSI International, 1131 N Warson Rd Bldg D St. Louis, MO 63132, United States

Your feedback and inquiries are important to us. We strive to respond to all messages as swiftly as possible. Thank you for choosing LSI International, and we look forward to assisting you!

We have a 30-day return policy, which means you have 30 days after receiving your item to request a return. To be eligible for a return, your item must be in the same condition that you received it, unworn or unused, with tags, and in its original packaging. You’ll also need the receipt or proof of purchase. To start a return, you can contact us at lsiinternationalcorp@gmail.com. If your return is accepted, we’ll send you a return shipping label, as well as instructions on how and where to send your package. Items sent back to us without first requesting a return will not be accepted. You can always contact us for any return question at lsiinternationalcorp@gmail.com. Damages and issues Please inspect your order upon reception and contact us immediately if the item is defective, damaged or if you receive the wrong item, so that we can evaluate the issue and make it right. Exceptions / non-returnable items Your satisfaction with LSI International, and the products you purchase, is of the highest importance to us. We will gladly accept the return, or exchange, of most products up to 30 days from the date of purchase. The return of any allowed products that have been opened, used, or have broken seals are subject to a 20% restocking fee. Original shipping and handling charges incurred are always non-refundable and will be deducted from any refund for the cost of returned items, including in the event of a Free Shipping promotional incentive being applied to an order. Once a return is made, this promotional incentive is negated and the cost incurred must be accounted for. The restocking fee will only be waived in the case of all returned items being unopened, unused, and in their original packaging. Missing Instruction Manuals, Quick Reference Guides, and any other original literature from a returned product will result in an automatic $5.00 fee deducted from any refunds issued for the costs of those items. If you are unsatisfied with a product, or find any defects due to manufacturing and/or workmanship, please contact us. Fulfillment mistakes that we make, resulting in the shipment of incorrect products to you, will also be accepted for return up to 30 days from the date of purchase. To make a return, or exchange, please contact Customer Service to get a Return Authorization number. We will be happy to provide the number and explain the procedure to you. Our process is simple - Clearly write the return authorization number on the outside of the product packaging so we can easily identify the order, ship to our warehouse, and we will credit the account used to make the purchase within 7 business days from the date we receive the returned items, or contact you to complete an exchange. Returns or exchanges cannot be accepted without a return authorization number. If your item was damaged during shipment, please contact us for assistance. Our customer service line is available M-F from 9am-5pm CST at (800)-832-0053, or feel free to lsiinternationalcorp@gmail.com. If you experience any issues, or technical difficulties, with a product you ordered, please contact Customer Service. This would be tied to a manufacturer warranty process and we will be more than happy to set up a technical support call for you. Ultrasound Returns: Portable Ultrasound may only be returned if the product has NOT been used. Used Ultrasound devices may not be returned due to sanitary health reasons set by the FDA. If you are attempting to return the device due to defect or malfunction with performance, this would go through the warranty and we ask you to please contact us for a warranty claim. Pillows and Cushions: Any pillows or cushions may only be returned if they are unused and in the same condition customer received the item with original packaging. We only sell our pillows and cushions brand new for sanitary reasons. Exchanges The fastest way to ensure you get what you want is to return the item you have, and once the return is accepted, make a separate purchase for the new item. Refunds We will notify you once we’ve received and inspected your return, and let you know if the refund was approved or not. If approved, you’ll be automatically refunded on your original payment method. Please remember it can take some time for your bank or credit card company to process and post the refund too.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Sale
Intelect RPW 2 - Shockwave Therapy Success
Sale price $17,305.60 Regular price $19,000.00 Save 9%
Sale
Richmar THERADOT Deep Oscillation Therapy Device
Sale price $4,999.99 Regular price $6,000.00 Save 17%
The Hottest Laser Therapy Device On The Market!
Richmar TheraTouch LX2 Cold Laser Therapy Device + 9 Diode Cluster Applicator
from $3,195.95
Recently viewed